TOOLS · CEPH
Ceph calculator
Estimate how much data you can store in a Ceph cluster with 3 to 128 nodes so that, after the failures you want to survive and the recovery, no OSD goes above the nearfull threshold. It also sizes block.db, RAM and network and estimates recovery time, with formulas and sources shown in full.
Calculate your cluster
It starts from 3 nodes with four 3.84 TB NVMe drives each in 3-way replication: 13.97 TiB in theory, but to allow for the loss of one drive you can store 8.28 TiB, with 5% imbalance between OSDs and block.db on the same drives at 2%. With three nodes, the copies lost with a whole node cannot be rebuilt. Change the inputs to match your cluster.
- Releases
- Ceph Squid 19.2 and Tentacle 20.2
Calculate your cluster
Recommended capacity 8.28 TiB. Scenario: no failure. Data: Guaranteed. Warnings: 0.
Recommended logical capacity, NVMe drives, model estimate
8.28 TiB
Allows for the loss of one OSD: after recovery the OSDs stay below nearfull (85%). Worst failure: one OSD on node 1.
Assumptions: data spread in proportion to capacity, one copy or chunk per domain, 5% imbalance between OSDs, block.db on the OSD drive at 2%.
- Rebuild limit
- 8.78 TiB
- Above this value, backfill after the failure stops at the backfillfull threshold and the rebuild does not complete.
- Write limit
- 9.28 TiB
- Above this value Ceph blocks writes (full threshold).
- Theoretical
- 13.97 TiB
- Raw divided by the number of copies, or by (k+m)/k with erasure coding.
- Raw
- 41.91 TiB
- 3 domains, 3 nodes.
No failures
Recovery, estimate
cannot be estimated
Pick a failure to estimate the recovery.
- Data you store
- 8.28 TiB, 19.8%
- Copies and parity
- 16.56 TiB, 39.5%
- Failure reserve
- 8.28 TiB, 19.8%
- Headroom before nearfull
- 7.94 TiB, 19.0%
- block.db on the same drive
- 0.84 TiB, 2.0%
Cluster map
3 nodes, before the failurePress ‘Simulate failure’ on one or more nodes, or the number of an OSD to fail only that drive: outcomes, recovery and fill levels update.
nearfull fill level of the fullest OSD above nearfull failed
With a single data pool on NVMe and a target of 100 PGs per OSD, you need 512 PGs; each OSD holds 128 PG instances on average and 128 at most, against a limit of 250. Calculate the PGs for every pool
To see this tab, pick a dedicated device in the block.db field of an HDD or SSD drive type: the rules side by side, how the OSDs map to the devices and a device failure simulation will appear.
Not all of these are recommendations: the pveceph 10% is what it allocates when you give no size and Ceph has none configured, not a measure of what is needed.
The dark line is the value the calculator recommends.
How the OSDs of a node are assigned to the DB devices
How RocksDB grows: for understanding, not for sizing
Since Squid the RocksDB levels start at 1 GiB and each is 8 times the previous one: 1, 8, 64, 512 GiB. With use_some_extra BlueStore also uses the space between levels, so the old 3, 30 and 300 GB steps no longer hold as a rule.
SSD and NVMe: what actually speeds things up
- DB and WAL on NVMe
- metadata and small writes; not a cache for data
- Pools per class
- an NVMe pool for VMs, an HDD pool for cold data
- Primary affinity
- picks the SSD OSD of a PG as primary, if there is one: reads go there, writes still wait for every copy
- Cache tiering
- deprecated since Reef: do not use it in a new cluster
Group A: 3 nodes, each with 4 NVMe OSDs
- Node RAM, Ceph rule
- 29.2 GiB
- 4 OSDs at 4 GiB of osd_memory_target each, plus 20%: 19.2 GiB. Add the Ceph services (6 GiB), the OS (4 GiB) and the VMs (0 GiB).
- Node RAM, Proxmox rule
- 42 GiB
- 8 GiB per OSD, 32 GiB in total, plus the same Ceph services, OS and VMs.
- CPU threads for Ceph
- 18-26
- Minimum and recommended, plus one thread for each MON, MGR or MDS service on the node. Threads, not physical cores.
- Network
- 25 Gb/s or more
- Dedicated to Ceph, with Corosync on a separate network. Fast NVMe drives may need 40 or 100 Gb/s.
- Sequential bandwidth of a node's drives
- 5.0 GB/s
- Compare it with the 25 Gb/s network, which carries at most 3.1 GB/s. Which of the two limits a recovery is estimated in the Capacity and failures tab.
- Traffic between OSDs per byte written
- 2.00 times
- For every byte the client writes, the primary sends a copy to each other OSD in the PG: size minus 1 bytes of traffic.
Group A: 3 nodes, each with 4 NVMe OSDs
- Node RAM, Ceph rule
- 29.2 GiB
- 4 OSDs at 4 GiB of osd_memory_target each, plus 20%: 19.2 GiB. Add the Ceph services (6 GiB), the OS (4 GiB) and the VMs (0 GiB).
- Node RAM, Proxmox rule
- 42 GiB
- 8 GiB per OSD, 32 GiB in total, plus the same Ceph services, OS and VMs.
- CPU threads for Ceph
- 18-26
- Minimum and recommended, plus one thread for each MON, MGR or MDS service on the node. Threads, not physical cores.
- Network
- 25 Gb/s or more
- Dedicated to Ceph, with Corosync on a separate network. Fast NVMe drives may need 40 or 100 Gb/s.
- Sequential bandwidth of a node's drives
- 5.0 GB/s
- Compare it with the 25 Gb/s network, which carries at most 3.1 GB/s. Which of the two limits a recovery is estimated in the Capacity and failures tab.
- Traffic between OSDs per byte written
- 2.00 times
- For every byte the client writes, the primary sends a copy to each other OSD in the PG: size minus 1 bytes of traffic.
Starting values from the Ceph and Proxmox VE documentation: measurements of your real workload will change the numbers. For drive bandwidth the calculator uses the mClock defaults, 150 MiB/s for HDDs and 1,200 MiB/s for SSDs and NVMe: they are configuration settings, not drive measurements.
Want a second opinion on this cluster? A summary of the calculation goes into your message: a Rackone systems engineer reviews it with you and proposes hardware and configuration.
Ask for a cluster designOn this page
How much usable space Ceph gives with 3-way replication
Dividing the raw capacity by three gives the theoretical space. The number that matters is a different one: how much data you can store so that, after the worst failure you want to survive and the recovery, the fullest OSD stays below the nearfull threshold (85% by default). The calculator calls it the recommended capacity and estimates it with ideal placement: data spreads across domains in proportion to capacity, with one copy or chunk per domain. The imbalance between OSDs is an explicit assumption, 5% by default, that you can change.
L = (threshold - block.db share) / (1 + imbalance)
a_d = capacity of domain d × L, in decreasing order
X* = min over j from 0 to w-1 of S_j / (1 - j/w)
logical capacity = X* / amplification
L is the maximum fill allowed for an OSD, net of block.db and imbalance; a_d is the usable space of domain d; w is the number of copies with replication, or k+m with erasure coding; S_j is the sum of the a_d excluding the j largest domains; the amplification is size with replication and (k+m)/k with erasure coding. A domain cannot hold more than X*/w, because every object has at most one copy or chunk per domain: this constraint is where both the space stranded by domains of different capacity and the failure reserve come from.
Worked example: 3 nodes with 4 OSDs of 3.84 TB, 3-way replication, host failure domain, block.db on a dedicated device. Raw capacity is 46.08 TB, or 41.91 TiB, and the theoretical capacity 13.97 TiB. With three nodes, the copies lost with a node cannot be rebuilt, because a fourth domain would be needed: the failure to survive therefore becomes the loss of one OSD. That OSD's data is rebuilt on the other three OSDs of the same node, whose usage grows by a third; to keep them below 85% you can store 8.91 TiB with no imbalance, 8.48 TiB with 5%.
Next to the recommended capacity the calculator shows two more values. The rebuild limit, based on the backfillfull threshold (90%): above it, backfill after the failure stops and the rebuild does not complete. The write limit, based on the full threshold (95%): above it, Ceph blocks writes.
Replication or erasure coding
3-way replication keeps three full copies of every object: amplification 3, min_size 2, reads from a single copy. Erasure coding k+m splits every object into k data chunks and m parity chunks: the amplification drops to (k+m)/k, that is 1.5 for a 4+2, at the cost of more CPU and more latency. To use an EC pool with RBD or CephFS you need allow_ec_overwrites, which enables partial writes.
You need at least k+m domains, and the Ceph documentation advises one more so that the pool can be rebuilt after a failure. With EC 4+2 on 6 hosts, losing a host leaves the data readable, but the lost chunks cannot be rebuilt; on 7 hosts they can.
Worked example: 7 nodes with 4 HDDs of 16 TB, the loss of one node to survive, no imbalance between OSDs and block.db on the same drives at 2% (the default). With 3-way replication you can store 96.62 TiB, with EC 4+2 193.25 TiB: twice as much, on the same drives.
What happens when a node fails
For every failure the calculator answers three questions. Is the data safe? Yes if the failure hits fewer domains than there are copies (with replication) or at most m domains (with erasure coding); beyond that it depends on how the PGs are placed, and the calculator says ‘not guaranteed’. Does I/O continue? Yes if every PG keeps at least min_size copies or chunks, the MONs stay in quorum and peering completes. Is full redundancy restored? Only if at least w domains remain and, after recovery, the fullest OSD stays below backfillfull, so that backfill can complete.
The worst failure, the one that sets the recommended capacity, is found by searching every combination of the failures to survive, not just by removing the largest node: with domains of different capacity the worst case can be a different one.
With 3 nodes and 3-way replication, after losing a node the data keeps two copies and I/O continues thanks to min_size 2, but the third copy is not rebuilt until the node comes back. In any case Ceph does not rebuild straight away: with the default settings it notices that an OSD is down in about 20 seconds (osd_heartbeat_grace) and marks it out after 10 minutes (mon_osd_down_out_interval). A whole rack is not marked out automatically (mon_osd_down_out_subtree_limit defaults to rack): in that case you start the recovery yourself.
How big block.db and WAL should be
With OSDs on HDDs, block.db on NVMe speeds up metadata and small writes. The published rules do not agree:
| Rule | Nature | RBD | CephFS | RGW |
|---|---|---|---|---|
| Ceph Squid and Tentacle | official recommendation | 1-2% | 1-4% | at least 4% |
| Ceph, development docs | recommendation in the development release | at least 2.5% | at least 2.5% | at least 2.5% |
| Red Hat Ceph Storage 8 | vendor recommendation | 1% | 4% | 4% |
| pveceph with no size given | allocation default | 10% | 10% | 10% |
The pveceph 10% is what it allocates when you give no size and Ceph has none configured: it does not measure the need. The calculator recommends 2% for RBD and 4% for CephFS, RGW and mixed workloads, the top of the official Squid and Tentacle recommendation for each workload. It is the calculator's own choice: the development documentation asks for at least 2.5%, and to follow it you only need to add a margin in the DB/WAL tab.
Worked example: with 12 OSDs of 16 TB per node and an RBD workload, 2% gives 320 GB of block.db per OSD, 3.84 TB per node before any margin. A 3.84 TB NVMe drive would be enough only if all of its capacity were allocatable. The Ceph hardware recommendations suggest up to 10 OSDs per NVMe drive, 15 with a PCIe Gen4 or newer NVMe: 12 OSDs fit on one device only if it is Gen4. And if a device fails, every OSD it serves stops with it: with one device that is all 12 OSDs of the node, with two devices 6. The DB/WAL tab of the calculator simulates exactly that failure.
The WAL sits on the DB device and uses its space, so it must not be counted twice; a separate WAL only makes sense on a device faster than the DB one. The RocksDB levels (1, 8, 64 and 512 GiB, with use_some_extra) explain how the DB grows but are not sizing steps: the old 3, 30 and 300 GB values no longer hold as a rule. When block.db fills up, the excess metadata spills over to the slow drive and Ceph raises BLUEFS_SPILLOVER.
SSD and NVMe: what actually speeds things up
- DB and WAL on NVMe: they speed up metadata and small writes; they are not a cache for data.
- Pools per device class: an NVMe pool for VM disks and an HDD pool for backups and cold data; each pool uses only its own class, and the calculator treats them separately.
- Primary affinity: among the OSDs of a PG it makes the SSD one the primary, if the PG has one; reads go there, but writes still wait for every copy.
- Cache tiering: deprecated since Ceph Reef, because it has long had no maintainer and may be removed; better not to use it in a new cluster.
RAM, CPU and network per node
The starting point for RAM is osd_memory_target, 4 GiB per OSD. It is a target, not a cap: Ceph frees memory on a best-effort basis and an OSD can go over it, so the calculator adds 20%. The Proxmox VE documentation suggests 8 GiB per OSD instead. With 12 OSDs per node that is 57.6 GiB with the first rule and 96 GiB with the second, plus MON (4 GiB), MGR (2 GiB), MDS if you run CephFS (5 GiB), the operating system and the VMs.
For CPU the calculator takes 1 to 3 threads per OSD on HDD, 2 to 4 on SATA SSD and 4 to 6 on NVMe as a starting point, plus one thread for each service (MON, MGR, MDS). These are threads, not physical cores.
Proxmox VE recommends at least 10 Gb/s dedicated to Ceph, 25 Gb/s or more with NVMe drives, and 40 or 100 Gb/s to make the most of fast NVMe, with Corosync on a separate network. Every GB a client writes generates more GB of traffic between OSDs: size minus 1 with replication, (k+m-1)/k with erasure coding for full writes, that is 2 GB with 3-way replication and 1.25 GB with EC 4+2. Partial erasure-coded writes can generate more.
How long recovery takes
The transfer time is the longest of four times, one for each possible bottleneck: the drives receiving the data, the network of the nodes receiving it, the surviving drives (which read and write at the same time) and the cluster network as a whole.
time = max( received by the busiest OSD / OSD bandwidth,
received by the busiest node / network bandwidth,
V × (read factor + 1) / (surviving OSDs × OSD bandwidth),
V × network factor / (surviving nodes × network bandwidth) )
V is the volume to rebuild; the factors are 1 with replication and k with erasure coding, because the primary reads k chunks to rebuild one. As the bandwidth of an OSD the calculator uses the mClock defaults (osd_mclock_max_sequential_bandwidth_hdd and _ssd): 150 MiB/s for HDDs, 1,200 MiB/s for SSDs and NVMe. They are configuration settings, not drive measurements: you can enter your own measurement in the advanced settings. The conservative scenario uses half of that bandwidth with the network at 50%, the optimistic one all of it with the network at 90%. It is an estimate, not a guaranteed speed: your own measurements will change the number.
Worked example: 5 nodes with 6 NVMe drives of 7.68 TB and a 25 Gb/s network, the cluster filled up to the recommended capacity, no imbalance between OSDs, block.db on the same drives at 2% and the loss of one node. There are 30.6 TB to rebuild: the transfer takes between 45 and 82 minutes and the bottleneck is the network. Failure detection and, with the default settings, the 10 minutes before the OSDs are marked out come on top.
How we calculate: formulas and sources
Model 1.2.0, dated 19 October 2026, for Ceph Squid 19.2 and Tentacle 20.2; Proxmox VE 9.2 installs Tentacle 20.2.1 by default. The calculator engine is checked against an independent reference implementation on 22 capacity cases from 3 to 128 nodes, failure scenarios, recovery estimates, PGs and block.db, and the worst-failure search against an enumeration of every combination.
Left out of version 1: several protection schemes on the same drive class, pools spanning classes, custom CRUSH rules beyond OSD, host and rack, stretch clusters, compression, small-object amplification and client performance.
- Ceph, pools, size and min_size
- Ceph, erasure coding
- Ceph, nearfull, backfillfull and full thresholds
- Ceph, when an OSD is marked out
- Ceph, BlueStore and block.db (Tentacle)
- Red Hat Ceph Storage 8, BlueStore
- Ceph, hardware recommendations
- Ceph, mClock and sequential bandwidth
- Ceph, cache tiering deprecation
- Proxmox VE, hyper-converged Ceph
Designing a Proxmox cluster with Ceph?
We design clusters from 3 nodes upwards: drives, network, block.db and protection sized for your workload, with failure testing before production.
Ceph calculator FAQ
How much usable space does Ceph give with 3-way replication?
With 3-way replication the theoretical capacity is a third of the raw capacity, but to survive a failure while staying below the 85% nearfull threshold you can store less. Three nodes with 4 x 3.84 TB, allowing for the loss of one OSD, give about 8.9 TiB out of 41.9 TiB raw; five nodes with 6 x 7.68 TB, allowing for the loss of one node, about 47.5 TiB out of 209.5 TiB. Both values assume no imbalance between OSDs and block.db on a dedicated device.
How many nodes does Ceph need on Proxmox?
For Ceph on Proxmox VE the practical minimum is 3 nodes, and the Proxmox documentation recommends at least 12 OSDs spread across them. With 3 nodes and 3-way replication, though, after losing a node the third copy is not rebuilt until the node comes back: to get back to three copies on the remaining nodes you need at least 4 nodes.
What does min_size 2 do, and why not min_size 1?
In Ceph min_size is the minimum number of copies with which a placement group still accepts reads and writes. With size 3, min_size 2 and a host failure domain, the cluster keeps working after losing a node, once peering completes. With min_size 1 it accepts writes on a single copy, and the Ceph documentation warns that in production this risks data loss.
Erasure coding or replication: when is EC worth it?
Erasure coding pays off for large, rarely modified data such as backups, archives and object storage: an EC 4+2 pool takes 1.5 times the data instead of 3. It costs CPU and latency, and it needs at least k+m domains, better k+m+1: at least 6 nodes for a 4+2, 7 to rebuild after a failure. VM disks usually stay on 3-way replication.
How big should block.db be for an HDD OSD?
For an OSD on HDD the Ceph Squid and Tentacle documentation suggests a block.db of 1 to 2% of the OSD size for RBD and at least 4% for RGW; the development docs say at least 2.5%. On a 16 TB drive that is 160-320 GB for RBD: the calculator recommends 2%, or 320 GB, and you can add a margin.
Do I need a separate WAL in Ceph?
Usually not: in Ceph the WAL sits on the block.db device and is part of its space. Separating it only makes sense on a device faster than the DB one, and a few GiB per OSD are enough: the calculator counts 2.
How much RAM does a Ceph OSD need?
Ceph has an osd_memory_target of 4 GiB per OSD and the process can go over it, so it makes sense to start from about 4.8 GiB; the Proxmox VE documentation suggests 8 GiB per OSD. MON, MGR, the OS and the VMs come on top: with 12 OSDs per node that is 57.6 or 96 GiB for the OSDs alone.
What network does Ceph need, 10 or 25 Gb/s?
Ceph needs at least 10 Gb/s of dedicated network; with NVMe drives Proxmox VE recommends at least 25 Gb/s, and very fast drives may need 40 or 100 Gb/s. In a recovery the network is often the bottleneck: six NVMe drives in a node read more data than a 25 Gb/s network can carry.
What are nearfull, backfillfull and full in Ceph?
They are the three Ceph OSD fill thresholds, 85%, 90% and 95% by default. At nearfull Ceph warns; at backfillfull it refuses backfill to that OSD, so rebuilding data onto it stops; at full it blocks writes. The calculator sizes on nearfull after the failure.
Can I still use Ceph cache tiering?
It still works, but it has been deprecated since Ceph Reef: it has long had no maintainer and may be removed without much notice, so it is better not to use it in a new cluster. To speed up an HDD cluster, put block.db and WAL on NVMe or split the pools by device class.
What happens if I lose a node in a 3-node Ceph cluster?
In a 3-node Ceph cluster with 3-way replication the data keeps two copies and I/O continues with min_size 2, but the third copy is not rebuilt until the node comes back: there is no fourth node to put it on. If a second node fails in that window, a single copy is left and, with min_size 2, I/O stops.
Do I need Ceph for a Proxmox cluster, or is ZFS replication enough?
Ceph is not mandatory for a Proxmox cluster. ZFS replication copies VM disks between nodes at intervals, every 15 minutes by default, so if a node fails and you restart its VMs from the replica, you lose the changes made since the last replication; Ceph writes every piece of data to several nodes synchronously. Ceph needs at least 3 nodes, a fast network and more drives: for 2 or 3 nodes with a few VMs, ZFS replication can be enough.
Is Ceph deprecated?